In some rare cases (especially related to emergency situations in env) we can see that one or more of workflows have “in progress” status, however there no any launched sub-steps (streams). For example:

Image Added

Note: please do not confuse it with hanging extract-stream. In that case: we are able to expand workflow line in MT and see that there is stream in processing state (not workflow).

This page with help you unstuck the process using built-in EJM instruments:

Table of Contents

Reset Sequencer Using eagle_ml-2-0_default_cm_sequencer_cleanup

Reset current stuck process



Reset the entire queue






...

In case of sequencer getting stuck, we suggest checking estar/tpe/cfg/msgcenter/msgservice.ini config file first of all.

SplitBatchSize parameter should not be a large number, preferred value is 2, in some cases, 1 - it is responsible for memory consumption and values like 100 may harm processing.

In case of sequencer getting stuck, our cleanup stream can work in several modes - either remove the entire queue or remove only the current (stuck workflow, including the case when you use PROCSEQID). Command:


Code Block
languagetext
1176:CUR_eagle_wrf_generic_load:1177:INTRADAY:

unstucks it.